TRL-onlineTOC-B Specification

 

Start- up Kit

included in the standard pack, for immediate commissioning to operate the instrument at site, for limited number of runs, however a consumables kit is recommended for a year of smooth operation

Ambient Temperature

between 5°C and 40°C is good for proper operation

Waste Liquid Disposal

achieved automatically by peristaltic pump

Fluid Flow Controls

fluid flow for accurate and repeatable injection is achieved through 3 peristaltic pumps plus a 6-port solenoid driven valve

Lifelong remote support

Available

Enclosure

NEMA 4 / IP54 compliant and either wall mount or floor standing use is possible

Compliance with Standard Methods

5310B, EPA 415.1, ISO 8245:1999, DIN1484:1997

Data Storage and Data Presentation

up to 9999 recent results should be saved and stored, on the basis of "first in first out" method; graphical trend presentation is available on the display and initiated by the operator

Analog Output Options

0-10 VDC and 4-20 mA analog output options are available for future upgrade

Controller Options

Communication and available digital outputs: via RS232; date and time, up to 3 measured parameters and error messages; profibus, modbus and ethernet options are available as adders

Monitoring

the monitor is designed for continuous operation

Measured Parameters

TC  by operator's selection
TOC by operator's selection
IC optional additions
TN optional additions

Dual Zone High Temperature Combustion Technology

the higher temperature zone is adjustable between 600-1000°C

Setting TOC Range

Range is set from 0-5mg/L to 0-1,000mg/L TOC, operator adjustable. 1000mg/L TOC is achieved without dilution of the sample

Limit of Detection

0.1mgC

Measuring method

High Temperature Catalytic Oxidation (HTCO); TOC is analyzed by direct NPOC measurement, IC removal is achieved by air sparging and acidification

CO2 Measuring

sensor for carbon analysis is nondispersive infrared detector (NDIR)

Analysis Cycle Time

Depends on number of wash cycles, however it is arranged by the operator; nominally between 5 to 20 minutes

Sampling

Samples at 1 to 2 bar-absolute are introduced without problem, by getting use of internal sampling pump

Air Flow Rate

Operator adjustable and nominally about 200mL/min,

Sample Temperature

5°C to 50°C is affordable

Carrier Gas

Hydrocarbon and CO2 free air at 2-6 bar

Weight

90 kg

Power Requirement

230 VAC 50/60 Hz; 1200VA

Dimensions (HWD)

138x70x36cm, including wall mount and hanging attachments

Shipment

via airfreight. The equipment is packed in a wooden cradle

Online TOC Analayzer
facebook
twiter
linkedin

TRLInstruments® Process and Equipments Technologies; Development Design and Manufacturing Company

location
info@trlinstruments.com

1328. Cadde, Demirağ Apt. No: 14/5 Aşağı Öveçler / Çankaya 06460 Ankara ᆞ Türkiye

 T:   +90 (312) 472 73 96   E:  info@trlinstruments.com

Manufacturer

CARBON ANALYZER

TOC ANALYZER

NITROGEN ANALYZER

CHEMICAL REACTORS

REACTION SYSTEMS

FLOW CONTROLLERS

BIOREACTORS

FERMENTERS

Product    Company    News    Contact

Analysis and research equipment for
a better environment and better future

www.trlinstruments.com